Home  /  Blog  /  Buying Guide
Buying Guide

How Much Wire Is Required for a 2BHK or 3BHK House?

Coils of house wiring cable stacked on racks at an electrical distributor warehouse in Bangalore

Wire is the second-largest line on a house electrical bill and the easiest one to over-order. Contractors quote coils generously because leftover wire belongs to them, not to you. Here is how to work out the real number.

The method: count points, not square feet

Square footage is a poor predictor because a compact 3BHK and a spread-out 2BHK can need the same wire. Count circuits instead:

  • Light and fan points — run on 1.0 or 1.5 sq mm.
  • 5A/6A socket points — 1.5 sq mm.
  • 16A power sockets — 2.5 sq mm.
  • AC, geyser, oven — 4.0 sq mm.
  • Meter to distribution board — 6.0 sq mm, occasionally 10.0.

Each point needs wire from the DB to the point and back, plus vertical drops, plus roughly 15% for bends, loops and wastage.

The quick estimate

A working rule for Bangalore homes: average run length per point is 9–14 metres of each conductor. Multiply points by run length, by the number of conductors (phase, neutral and earth — so three), then divide by 90 to get coils.

Wire size2BHK (~70 points)3BHK (~110 points)Typical use
1.0 sq mm3–4 coils5–7 coilsLights, fans
1.5 sq mm4–6 coils7–10 coilsLight circuits, 6A sockets
2.5 sq mm3–5 coils5–8 coils16A power sockets, kitchen
4.0 sq mm1–2 coils2–4 coilsAC, geyser, oven
6.0 sq mm1 coil1–2 coilsMains, meter to DB
Earth (green)2–3 coils4–5 coilsAll circuits

A 90m coil is the standard house-wire pack in India. Some brands also sell 180m and 300m coils, which cost less per metre and are worth it on larger houses.

Why 90m coils, and when to buy bigger

The 90m coil is the industry standard and the easiest size to verify, return and account for. If your house needs four or more coils of a single size, ask for 180m or 300m coils instead — the per-metre rate drops and there is less joint wastage. We explain the trade-off in our guide on why 90m coils are the safe default.

Three checks on the estimate you were given

  1. Does the coil count roughly match the point count? If a 2BHK estimate shows 20 coils, ask which circuits need them.
  2. Is 4.0 sq mm present at all? An estimate with no 4.0 sq mm means the ACs and geyser are being run on 2.5 — which is undersized for most installations.
  3. Is earth wire quantity roughly equal to the phase wire? Every circuit needs an earth conductor; a low earth-wire number usually means earthing is being skipped on socket circuits.

Buy slightly short, top up later

Order about 90% of your estimate and top up once the electrician has actually pulled the first floor. Wire is available next day across Bangalore, so there is no reason to carry three spare coils — and unused coils have a way of leaving site.

Use the wire quantity calculator to run your own numbers, and the wire size calculator to confirm which size each circuit needs.

Send your list on WhatsApp for an exact quote within 60 minutes. Approximate ranges on this page are for planning; WhatsApp 88676 76700 for today's firm rate, with no pressure to buy.

Frequently asked questions

How many coils of wire are needed for a 2BHK house?
Typically 12 to 20 coils of 90m in total: 3–4 coils of 1.0 sq mm, 4–6 of 1.5, 3–5 of 2.5, 1–2 of 4.0, one of 6.0 and 2–3 coils of earth wire. The exact number depends on point count, floor layout and the distance from the meter to the distribution board.
How many coils of wire does a 3BHK house need?
Usually 24 to 36 coils of 90m across all sizes, for roughly 110 points. Larger or multi-floor homes with long cable runs from the meter can go higher, and houses with many air conditioners need noticeably more 4.0 sq mm.
How do I calculate house wire quantity myself?
Count the points on each circuit type, assume an average run of 9 to 14 metres per point, multiply by three conductors for phase, neutral and earth, add about 15% for bends and wastage, then divide by 90 to get the number of coils per size.
Is a 90m coil the standard wire pack in India?
Yes, the 90m coil is the standard house-wire pack and the easiest size to verify and account for. Brands also sell 180m and 300m coils, which cost less per metre and are worth buying when a single size needs four or more coils.
Should I buy extra wire to be safe?
No. Order about 90% of your estimate and top up after the first floor is pulled. Wire is delivered next day across Bangalore, so surplus coils only tie up money and have a habit of disappearing from site.
How can I tell if my contractor over-quoted the wire?
Check three things: whether the coil count is proportionate to the point count, whether 4.0 sq mm appears at all for AC and geyser circuits, and whether earth wire quantity is roughly comparable to the phase wire. A missing 4.0 sq mm line or very little earth wire indicates corners being cut, not savings.

Ready to order for your home?

Upload your wiring list for an instant quote — 100% original material, free next-day delivery across Bangalore.

Keep Reading

More guides

Building your home? Buy from the best brand distributor.

100% genuine, QR-verified material · free next-day delivery across Bangalore · pay on delivery — and 35 years of trust behind every order. Exact quote on WhatsApp within 60 minutes.